主要特性與技術指標
- 10 MHz 到 50 GHz
- 2 端口或 4 端口,具有兩個內置信號源
- 126 dB 系統動態范圍和 129 dB 接收機動態范圍、32,001 點、32 通道、5 MHz IF 帶寬
- 高輸出功率(+16 dBm)、低諧波(-60 dBc)和寬功率掃描范圍(41 dB)
- 動態精度――在接收機端使用 0.1 dB 壓縮和 +15 dBm 輸入功率
- 在 10 Hz IFBW 時僅有 -111 dBm 的低本底噪聲
描述
廣泛的單次連接測量應用軟件
PNA-X 網絡分析儀是功能、最靈活的單次連接微波測試引擎,可測量放大器、混頻器和頻率轉換器等有源器件。目前它提供以下五種頻率型號供您選擇:13.5、26.5、43.5、50 和 67 GHz,可滿足您特定的器件測試需求。PNA-X 具有內置的第二個信號源、合路器和內部信號路由開關,能夠提供的可配置性。取代機架和堆疊
PNA-X 可以取代機架安裝式和堆疊式設備,減少您需要使用的設備數量。應用軟件包括:
· S 參數(連續波和脈沖)
· 噪聲系數
· 增益壓縮
· 互調和諧波失真
· 轉換增益/損耗
· 真正差分激勵
· 毫米波
· 非線性波形和 X 參數®表征
· 天線測試
選件:
N5245A-008 | Pulsed-RF Measurements |
N5245A-010 | Time-domain measurements |
N5245A-020 | Add IF inputs |
N5245A-021 | Add pulse modulator to internal first source |
N5245A-022 | Add pulse modulator to internal second source |
N5245A-025 | Add four internal pulse generators |
N5245A-028 | Noise figure measurements using standard receivers |
N5245A-029 | Fully-Corrected Noise-Figure Measurements to 50 GHz |
N5245A-080 | Frequency offset measurements |
N5245A-082 | Scalar calibrated converter measurements |
N5245A-083 | Vector and scalar calibrated converter measurements |
N5245A-084 | Embedded LO measurements |
N5245A-086 | Gain compression application |
N5245A-087 | Intermodulation distortion measurements |
N5245A-088 | Source phase control |
N5245A-118 | Fast CW mode |
N5245A-1A7 | Calibration + Uncertainties + Guardbanding |
N5245A-1CM | Rack mount kit for installation without handles |
N5245A-1CP | Rack mount kit for installation with handles |
N5245A-200 | 2 ports, single source |
N5245A-219 | Add extended power range and bias-tees to 2 port analyzer |
N5245A-224 | Add internal second source, combiner and mechanical switches to 2-port analyzer |
N5245A-301 | Application for use with standard CalPods |
N5245A-302 | Application for use with temperature-characterized CalPods |
N5245A-400 | 4 ports, dual source |
N5245A-419 | Add extended power range and bias-tees to 4 port analyzer |
N5245A-423 | Add internal combiner and mechanical switches to 4-port analyzer |
N5245A-460 | Integrated true-mode stimulus application |
N5245A-510 | Nonlinear component characterization, full frequency range |
N5245A-514 | Nonlinear X-Parameters |
N5245A-518 | Nonlinear pulse envelope domain |
N5245A-520 | Arbitrary load impedance X-parameters |
N5245A-551 | N-port calibrated measurements |
N5245A-897 | Built-in performance test software for inclusive calibration, perpetual license |
N5245A-898 | Built-in performance test software for standards compliant calibration, perpetual license |
N5245A-A6J | ANSI Z540-1-1994 Calibration |
N5245A-H08 | Pulsed - RF Measurements |
N5245A-UK6 | Commercial calibration certificate with test data |
N1966A | Pulse/IO Adapter |
N6171A | MATLAB Software |
N6171A-M01 | MATLAB-Basic Package, individual license - node-locked |
N6171A-M02 | MATLAB-Standard Package, individual license - node-locked |
N6171A-M03 | MATLAB-Advanced Package, individual license - node-locked |